The advanced semiconductor diode laser method of hair removal stands out for its absolutely permanent result with 10Hz fast speed and absence of side effects treatment. We just have to show up to the beautician or doctors with shaved skin areas. To carry out the final laser treatment it is used a professional conductive neutral gel , meanwhile, it's also ensure a better smoothness of the handpiece. The hair follicles absorb the spefic wavelength energy turn to the heat, to make sure we can hit the largest number of hair follicles to remove the unwant hairs in 3 or 4 treatments.
Diode laser technology is the newest advanced one in the world market . The most easy and safest operation ways are suitable for all the personal and beauty salon and clinics . The triple wavelength energy make the hair loss without injury surrounding tissue is highly proved to be the most effective treatment method .
How is the 3 wavelength working for hair removal ?
Triple Wavelength Diode laser hair removal system combine with the 808nm and 1064nm 755nm wavelength in one treatment handle . A new hair removal treatment technology is upgraded based on the single 808nm wavelength laser . The traditional single 808nm wavelength have been proved for the mostly hair types and the most regular skin types effectively, but for the white brown or light hairs , it will need more treatment sessions and less treatment efficiency around 40%~50% result . Another two wavelength 755nm and 1064nm are complement imporotant to the 808nm wavelength .755nm wavelength can be absorded easily by the light color skin type and fine tiny hairs , especially for the skin type I and the tine hair on upper lip or forehead; In the meantime,the invisible light 1064nm light could be working on the dark skin safety.
How the diode laser treatment work with TEC cooling ?
The body unwant hair removal is accomplished when destroying hair follicular unit by thermal damage of the diode laser light energy and thus inhibiting future hair regrowth by the follicle. The widely optional pulse duration (5-400ms) of 808nm ,755nm or 1064nm wavelength diode laser system can produce thermal damage in hair matrix stem cells and ensure follicular destruction. In order to minimize and reduce the uncomfortable of thermal damage to surrounding skin tissue, an efficient TEC skin-cooling system (Sapphire surface contact cooling tip with adjustable cooling levels) is used to chill the skin during treatment period. Therefore, The triple wavelength diode laser has better effectiveness for hair removal for various hairs and skin type even for the dark skin.
The priciple of the 3 wavelength diode laser:
Diode laser hair removal technology adopt the selective dynamics of 808nm and 755nm or 1064nm wavelength light ,Through the pores in the skin into the root of the hair follicles . The hair follicles will absorb the light energy and converted into heat , then to damage the follices and get the permanently hair removal . As the feedback of the clients , the 755nm wavelength could be aborded effeciently by the light brown hair color ; Meanwhile the 1064nm wavelength is the most safty wavelength to work on the dark skin type even for the skin type 6 .
Diode laser treatment must know items:
1. Prior to treatment, the physician must first get a detailed history, rule out any disorders that may contraindicate this treatment and finally physically inspect the treatment area.
2. Cosmetics should be removed with non-alcohol containing neutral cleansing agent such as Bactolinä, Cetaphilä Gentle Skin Cleanser or Celeteque Facial Wash.
3. Apply a generous amount of cooled gel (non-tinted) on the treatment area.
4. A slight erythema may appear after the procedure. This is normal and will fade gradually in a few minutes to hours.
5. Always record the parameters, fluence, shots and the area treated after each treatment.
6. Apply a cold compress prior to proceeding to the next treatment area.
7. Avoid use of cosmetics for 24 hours after each treatment.
8. Avoid sun exposure after each treatment
Item | Descriptions |
Control panel | 10.4 inch LCD touch screen |
Working Frequency | Adjustable range: 1HZ ~10HZ ; Recommend range: 3HZ ~6HZ ; |
Power of the diode laser | 600W~1200W |
Wavelength of laser | Treatment head 1: 755nm+808nm wavelength Treatment head 2 |
Light guidance | Sapphire |
Energy of laser | 1~120J/cm2 |
Laser bars | 10bars~36bars |
Alarm system | Temp alram + water alarm + lighting alarm |
Safety dectection | Always |
Rate power of the machine | 2500W |
Cooling system | Semicondutor refregirator cooling + Water cooling + Fans cooling |
Size of the treatment area | 12mmx20mm(standard) |
Power | AC230V±10%,50Hz±1Hz AC110V±10%,60Hz±1Hz |
Net weight | 45kgs |
Package size | 66cm*57cm*60cm |
Post operative nursing care
l Sun avoidance
As with other forms of treatment, the treatment area should be protected from sunlight exposure. An SPF 15 or greater physical-sun block is recommended. Avoidance of direct exposure is also recommended.
l Advice of some treatment area
For axillary hair treatment , it is recommended that deodorants and shaving be avoided for the 24-48 hours after treatment.
l Cosmetic
There is no contraindication to wear make-up after treatment. Likewise the patient may return to work immediately after treatment.
l Follow-up Treatment
The treatment duration of Diode laser therapy extends for a few months. Patients should be reminded of there follow up schedule as to maximize the efficacy of the treatment. Please refer to the provided treatment parameter chart for the treatment intervals.
l Side effect
If at any point of treatment an adverse reaction is noted, hold treatment apply a cold compress and review your parameter setting. The cold compress may be needed for 5 to 10 minutes or until the adverse reaction is remedied.